Specifications |
General |
Max Connected Capacity (Btu/h) | 24,000 |
SEER | Dependant on Indoor |
Min Cooling Capacity (Btu/h) | 6000.0 |
HSPF | Dependant on Indoor |
Heating COP | Dependant on Indoor |
Min Heating Capacity (Btu/h) | 7,200 |
Refrigerant Type | R410A |
De-Hum (Pints/Hr) | N/A |
Power Voltage | 208/230V-1Ph-60Hz | Construction |
Breaker Size | 25A | Outdoor unit shall be galvanized steel with a |
RLA Cooling/Heating (Amps) | 8.6/9.0A | baked on powder coated finish for durability |
Controls | DDC |
Heat Exchangers |
Outdoor Unit | MH050FXCA2A | The heat exchangers shall be mechanically bonded fin |
Outdoor Noise Level (Db) | 50/51 | to copper tube. |
Width (Inches) | 34 5/8" |
Height (Inches) | 25 1/8" | Refrigerant System |
Total Depth (Inches) | 12 1/4" | Compressor shall be a single hermetically sealed DC |
Weight (lbs) | 131 | Inverter drive rotary type |
Refrigerant shall be R410A. |
Line Sets | Refrigerant flow to each Indoor unit shall be controlled |
Size | 1/4" & 3/8" x 2 | by Electronic Expansion Valve. Maximum of 2 Indoor |
Max Line Set Length inc | 100ft | units can be connected to this unit |
Max Vertical Separation of | 50ft |
Max Individual line set length | 75ft | Rated Matches |
Charged with R410A for | 25ft | Unit can be matched as follows |
Addl R410A charge required | 0.2oz/ft over 25ft | 2 x MH026 units either Neo Forte or Slim Duct |
1 x MH026 + 1 x MH035, either neo Forte or Slim Duct |
Certifications | 2 x MH035 units either Neo Forte or Slim Duct |
Safety | UL & Ulc | Using a single Indoor unit is not allowed |
Performance | ARI Certified |
ARI Certification Reference # | TBA | Outdoor Fan |
The outdoor unit fan shall be a propeller type driven |
Warranty | 5 Years Compressor | by a single BLDC fan motor for optimum efficiency and |
3 Years Parts | accurate head pressure control |
120 Days ltd labor |
Controls |
Options | 25 or 50ft Line Sets | Control signal shall be a DDC type signal |
Condenser Brackets | Controls shall integrate with a BMS system |
Control wiring shall require 16AWG shielded wire |
Unit operating range shall be |
Cooling 23 DegF to 115 DegF |
Heating 5 DegF to 75 DegF |