Reliable monitoring of liquids and gases in pipes
Variable process connection using adapters
Easy setting of the switch points for quick set-up
Robust stainless steel housing for use in harsh industrial environments
LED bar graph for indication of switch point and flow
Product characteristics
Number of inputs and outputs Number of digital outputs: 1
Process connection M18 x 1,5 Internal thread
Application
Media Liquids; Gases
Medium temperature [?C] -25...70
Pressure rating [bar] 300
Liquids
Medium temperature [?C] -25...70
Gases
Medium temperature [?C] -25...70
Electrical data
Operating voltage tolerance [%] -15...15
Operating voltage [V] < 24 AC / 18...36 DC; (to SELV/PELV)
Current consumption [mA] < 80
Protection class III
Power-on delay time [s] 10
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 1
Outputs
Total number of outputs 1
Output signal switching signal
Number of digital outputs 1
Output function normally open
Contact rating 2 A, 24 V AC/DC; (according to EN 50178 SELV/PELV)
Short-circuit protection no
Overload protection no
Measuring/setting range
Probe length L [mm] 45
Liquids
Setting range [cm/s] 3...300
Greatest sensitivity [cm/s] 3...100
Set point SP [cm/s] 20
Gases
Setting range [cm/s] 200...3000
Greatest sensitivity [cm/s] 200...800
Accuracy / deviations
Repeatability [cm/s] 1...5
Note on repeatability
for water 5...100 cm/s; 25 ?C
Factory setting
Temperature drift [cm/s x 1/K] 0.1; (for water 5...100 cm/s; 10...70 ?C)
Max. temperature gradient of medium [K/min] 300
Switch point accuracy [cm/s] ? 2...? 10; (for water 5...100 cm/s; 25 ?C; Factory setting)
Hysteresis [cm/s] 2...5; (for water 5...100 cm/s; 25 ?C; Factory setting)
Reaction times
Liquids
Response time [s] 1...2; (for a temperature gradient: 1 K/min)
Gases
Response time [s] 1...10
Software / programming
Adjustment of the switch point pushbuttons
Operating conditions
Ambient temperature [?C] -25...60
Storage temperature [?C] -25...100
Protection IP 65; IP 67
Tests / approvals
EMC
DIN EN 60947-5-9
Shock resistance
DIN EN 60068-2-27 20 g (11 ms)
Vibration resistance
DIN EN 60068-2-6 5 g (55...2000 Hz)
MTTF [years] 351
Mechanical data
Weight [g] 229.5
Dimensions [mm] M18 x 1.5
Thread designation M18 x 1.5
Material stainless steel (1.4404 / 316L); stainless steel (1.4310 / 301); PC; PBT-GF20; EPDM/X
Materials (wetted parts) stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A
Process connection M18 x 1,5 Internal thread
Displays / operating elements
Display
Function 10 x LED, three-colour
Remarks
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12
*** Factory New, Original Equipment OEM Daikin McQuay, IMF Efector 1 Year Manufacter Warranty ***